Small AC Gear Reducer Motor 250W

The 6RK series AC gear motor (120–250W) is built with a durable 100mm frame and engineered for high-torque, heavy-duty industrial applications. It delivers powerful output, stable speed performance, and excellent reliability under continuous operation. With flexible single-phase and three-phase configurations, this motor is ideal for conveyors, automated production lines, and high-load mechanical systems.

  • Output Power: 120W – 250W
  • Voltage: 110V / 220V / 380V (Single-phase & Three-phase options)
  • Rated Speed: 1350 – 1550 r/min
  • Rated Torque: 740 – 1840 mN·m

List of motor characteristics

6RK AC reduction motor (120~250W) (100mm)

Motor ModelSpecsOutput Power
W
Voltage
V
Frequency
Hz
Current
A
Starting TorqueRated TorqueRated
Revolution
r/min
Capacity/Ve
μF/VAC
JWD TypesmN.mgf.cmmN.mgf.cm
6RK120GU-CFReversible
30min
1201-phase
220V
501.215751575012601260013508/450
6RK120A-CF601.4122512250980980015508/450
6RK120GU-AFReversible
30min
1201-phase
110V
501.80157515750126012600135032/250
6RK120A-AF6021225122509809800155032/250
6RK120GU-UF——1203-phase
380V
500.4611001100088088001350——
6RK120A-UF600.42925925074074001550——
6RK140GU-CFReversible
30min
1401-phase
220V
501.3128512850102810280135010/450
6RK140A-CF601.431078107808638630155010/450
6RK140GU-AFReversible
30min
1401-phase
110V
502.20128512850102810280135040/250
6RK140A-AF602.41078107808638630155032/250
6RK140GU-UF——1403-phase
380V
500.551285128501028102801350——
6RK140A-UF600.4610781078086386301550——
6RK160GU-CFReversible
30min
1601-phase
220V
501.4157515750126012600135010/450
6RK160A-CF601.461225122509809800155010/450
6RK160GU-AFReversible
30min
1601-phase
110V
502.60157515750126012600135040/250
6RK160A-AF602.81225122509809800155036/250
6RK160GU-UF——1603-phase
380V
500.551468146801175117501350——
6RK160A-UF600.512321232098698601550——
6RK180GU-CFReversible
30min
1801-phase
220V
501.5183718370147014700135012/450
6RK180A-CF601.46154015400123212320155012/450
6RK180GU-AFReversible
30min
1801-phase
110V
502.80183718370147014700135048/250
6RK180A-AF602.6154015400123212320155048/250
6RK180GU-UF——1803-phase
380V
500.801825182501460146001350——
6RK180A-UF600.751457145701180118001550——
6RK200GU-CFReversible
30min
2001-phase
220V
501.55145814580141414140135010/450
6RK200A-CF601.5129412940123212320155010/450
6RK200GU-AFReversible
30min
2001-phase
110V
503.00148514850141414140135040/250
6RK200A-AF602.8129412940123212320155036/250
6RK200GU-UF——2003-phase
380V
500.901600160001450145001350——
6RK200A-UF600.871386138601260126001550——
6RK250GU-CFReversible
30min
2501-phase
220V
501.6202020200183718370135012/450
6RK250A-CF601.55170017000154015400155012/450
6RK250GU-AFReversible
30min
2501-phase
110V
503.30202020200183718370135048/250
6RK250A-AF603.2170017000154015400155048/250
6RK250GU-UF——2503-phase
380V
501.302022202201840184001350——
6RK250A-UF601.21760176001600160001550——
  • Parameters in above table refer to motor alone,without any load device.
  • Permissible change in rated speed and rated current of the motor is within the range of±5%.

Outline dimension drawing

66666

Allowable load for the gear motor

Geared-down
parameter
Synchronous speed500300200150120100756050413730252015121087653
Ratio357.51012.5152025303640506075100120150180200250300500
Max allowable
load
120WKg.cm/N.m21.5
2.11
36
3.52
54
5.28
69.8
6.85
85
8.45
103
10.2
139
13.6
172
16.9
209
20.5
226
22.14
251
24.6
315
31
140Wkg.cm/N.m25.1
2.46
42
4.11
63
6.16
73.5
8.02
99.2
9.86
120
11.8
147
14.4
200.7
19.73
221
21.7
238
23.4
265
26
330
32.5
160WKg.cm/N.m28.7
2.81
48
4.69
72
7.04
87
8.53
113.3
11.27
137.3
13.53
174
17
229
22.6
261
25.6
285
28
317
31.1
396
38.8
440
43
180Wkg.cm/N.m32.3
3.17
54
5.28
81
7.92
94.7
9.28
127.5
12.68
154.5
15.23
189
18.7
237
23.2
284
27.8
310
30.1
344
33.4
430
42.2
440
43
200WKg.cm/N.m39.4
3.86
66
6.44
89.9
8.8
119
11.7
149
14.5
180
17.6
239
23.4
299
29.3
358
35.1
392
38.4
435
42.6
440
43
250Wkg.cm/N.m49.3
4.83
82.1
8.1
112
11
149
14.6
486
18.3
224
22
298
29.3
375
36.6
438
43
440
43
  • The speed is based on the synchronous motor speed reduction ratio as a benchmark calculated by dividing the value of.Actual speed will vary the size of the load changes in less than the values shown in2~15%.
  • Hope to the table of the reduction ratio is greater than the further reduction,it would be installed between the motor and the reducer reduction ratiio of 10 the middle of the reducer.
  • When the load torque exceeds the maximum allowable load torque gear motor,and a locked rotor situation exists,please slow down box at the junction of the output shaft and load torque limit device installed to ensure the normal operation gearbox.
Chat on WhatsApp +86-15058710888 manager@cntenchuan.com